Pumafix® TQV
2-component fast curing vinylester injection resin.
Pure resin based vinylester (styrene free).
INSTRUCTIONS FOR USE INSTALLATION INSTRUCTIONS IN SOLID BRICKWORK FACTORY
INSTALLATION INSTRUCTIONS IN HOLLOW/PERFORATED BRICKWORK FACTORY
| Anchor | Installation | Resistance | Permissible load | |||||
| Rod class 8,8 | Drill piece diameter d0 | Hole depth hef | Standard distance edges CCr | Standard distance anchors SCr |
Torque Tinst |
Charasteristic resistance NRk |
Concrete C20/25 | Concrete C20/25 |
| [mm] | [mm] | [mm] | [mm] | [N.m] |
Traction [kN] |
Traction [kN] |
Shear [kN] |
|
| M8 | 10 | 80 | 80 | 160 | 10 | 29,3 | 11,6 | 8,1 |
| M10 | 12 | 90 | 90 | 180 | 20 | 46,4 | 18,4 | 12,9 |
| M12 | 14 | 110 | 110 | 220 | 40 | 63,8 | 25,3 | 18,7 |
| M16 | 18 | 125 | 125 | 250 | 80 | 76,9 | 30,5 | 34,9 |
| M20 | 24 | 170 | 170 | 340 | 120 | 112,7 | 44,7 | 54,4 |
Safety factor of 2.52 load stress
APPLICATION TABLE FOT CORRUTAGED CONCRETE BARS
|
Bar diameter d5 |
Drill bit diameter d0 |
Permissible load Fs in C20/25 concrete. High tack 500 MPa corrutaged steel bar |
|||||||
| [mm] | [mm] |
Hole |
[mm] [kN] |
[mm] [kN] |
[mm] [kN] |
[mm] [kN] |
[mm] [kN] |
[mm]*1 [kN]*1 |
|
| 8 | 10 | Iv | 80 | 120 | 160 | 200 | 240 | 322 | |
| Fs [C20/25] | 5,4 | 8,1 | 10,9 | 13,6 | 16,3 | 21,9 | |||
| 10 | 12 | Iv | 100 | 150 | 200 | 250 | 300 | 403 | |
| Fs [C20/25] | 8,5 | 12,7 | 17 | 21,2 | 25,4 | 34,2 | |||
| 12 | 16 | Iv | 120 | 180 | 240 | 300 | 360 | 483 | |
| Fs [C20/25] | 12,2 | 18,3 | 24,4 | 30,5 | 36,6 | 49,2 | |||
| 14 | 18 | Iv | 140 | 210 | 280 | 350 | 420 | 564 | |
| Fs [C20/25] | 16,6 | 24,9 | 33,3 | 41,6 | 49,9 | 66,9 | |||
*1 Maximum loads according to elastic limit of 500 MPa corrutaged steel
380 ml 2-component cartridges. (application with special gun) and 280 ml. (application with mono-component product guns).Shelf life: up to 18 months in sealed original packaging, sheltered from weather conditions and humidity.
(Statistical data obtained under standard conditions)
| Density | 1.75 Kg/dm³ |
| Double the load times in wet conditions | |
| Min application temperature | 5º C |
| Max application temperature | 30º C |
| Working temperature interval after curing | from -40º C to 80º C |
| Application temperature | Open time | Curing time |
| 5º C | 15 min. | 120 min. |
| 10º C | 12 min. | 90 min. |
| 20º C | 6 min. | 45 min. |
| 30º C | 3 min. |
20 min. |
Calculation method: Fs (kN)= d0 x Iv x Ψ c / 100
d0 and Iv in mm, min. spacing 10 ds1 min. edge distance 5 ds
|
Concrete resistance class |
C12/15 | C16/20 | C20/25 | C25/30 | C30/37 | C35/45 | C40/50 | C45/55 | C55/60 | |
| (*) | de Ø 8 mm a 25 mm | 1,6 | 2 | 2,3 | 2,7 | 3 | 3,4 | 3,7 | 4 | 4,3 |
| (**) | 0,452 | 0,565 | 0,650 | 0,763 | 0,848 | 0,961 | 1,046 | 1,131 | 1,216 | |
| (*) | de Ø 26 mm a 32 mm | 1,6 | 2 | 2,3 | 2,7 | |||||
| (**) | 0,452 | 0,565 | 0,650 | 0,763 | ||||||
| (*) | Ø 34 mm | 1,6 | 2 | 2,3 | 2,6 | |||||
| (**) | 0,452 | 0,565 | 0,650 | 0,735 | ||||||
| (*) | Ø 36 mm | 1,5 | 1,9 | 2,2 | 2,6 | |||||
| (**) | 0,424 | 0,537 | 0,622 | 0,735 | ||||||
| (*) | Ø 40 mm | 1,5 | 1,8 | 2,1 | 2,5 | |||||
| (**) | 0,424 | 0,509 | 0,594 | 0,707 | ||||||
* Charasteristic interchange resistance for good anchorage conditions (EC2) ft (MPa)
** Factor according to concrete type Ψ c
Ψ c = 0,06 x π x ft x Ψs2 / γ s
γ s = 1,15 safety coefficient
Ψs = 1,5 high tack bar coefficient (1)
(1) For smooth bars use Ψs = 1,0
PERFORMANCE: NUMBER OF ANCHORS ACCORDING TO DIAMETER AND CARTRIDGE TYPE
| Anchorage | Concrete rods | Corrutaged concrete bars | ||
| Diámetro | 380 ml. | 280 ml. | 380 ml. | 280 ml. |
| 8 | 90/100 | 65/75 | 90/100 | 65/75 |
| 10 | 55/55 | 35/40 | 50/55 | 35/40 |
| 12 | 30/34 | 20/24 | 20/25 | 14/19 |
| 16 | 16/18 | 11/13 | 12/14 | 9/11 |
| 20 | 7/8 | 5/6 | 7/8 | 5/6 |
The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.
GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.
In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.
The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.