Pumafix® TQP
Injection resin for anchorage, 2-component and fast curing, resin-based polyester. Styrene-free. Multifunctional, for solid or hollow substrates.
Styrene-free, unsaturated polyester resin.
INSTALLATION INSTRUCTIONS FOR SOLID BRICKWORK
INSTALLATION INSTRUCTIONS FOR HOLLOW/PERFORATED BRICKWORK
Number of Anchors per drilled hole diameter
| Anchor | INSTALLATION IN HOLLOW SUBSTRATES | |
| Rod | Sieve 16/85 | Sieve 16/130 |
| 280 ml | 280 ml | |
| M8 | 11 | 7 |
| M10 | 11 | 7 |
| M12 | 11 | 7 |
| M16 | - | - |
| M20 | - | - |
|
Anchor |
INSTALLATION OF CONCRETE RODS |
| Rod | |
| 280 ml | |
| M8 | 65/75 |
| M10 | 37/40 |
| M12 | 22/25 |
| M16 | 11/13 |
| M20 | 5/6 |
See application tables for hole depth and diameter values
APPLICATION TABLE FOR RODS IN HOLLOW SUBSTRATES
| Anchor | Installation | Permissible loads | |||||||
| Nozzle |
Rod class 5.8 |
Drill piece diameter d0 | Drill depth | Hole depthhef | Torque Tinst | Hollow bricks fcm: 4,50 MPa | Concrete masonry units fcm: 6,00 MPa | ||
|
|
|
|
|
Traction |
Shears |
Traction |
Shears |
||
| 16/85 | M8 | 17 | 90 | 85 | 4 | 0,40 | 1,10 | - | - |
| 16/85 | M10 | 17 | 90 | 85 | 4 | 0,40 | 1,10 | - | - |
| 16/85 | M12 | 17 | 90 | 85 | 4 | 0,40 | 1,10 | - | - |
| 16/130 | M8 | 17 | 135 | 130 | 4 | - | - | 0,70 | 1,50 |
| 16/130 | M10 | 17 | 135 | 130 | 4 | - | - | 0,70 | 1,50 |
| 16/130 | M12 | 17 | 135 | 130 | 4 | - | - | 0,70 | 1,50 |
APPLICATION TABLE POR CONCRETE RODS
| Anchor | Installation | Resistance | Permissible load | |||||
| Rod class 5.8 | Drill piece diameter d0 | Hole depth h ef | Standard distance edges CCr | Standard distance anchors SCr | Torque Tinst | Characteristic resistance NRk | Concrete C20/25 | Concrete C20/25 |
|
[mm] |
[mm] |
[mm] |
[mm] |
[N.m] |
Traction [kN] |
Traction [kN] |
Shears [kN] |
|
| M8 | 10 | 80 | 80 | 160 | 10 | 14,7 | 4,9 | 5,8 |
| M10 | 12 | 90 | 90 | 180 | 20 | 20,5 | 6,8 | 9,2 |
| M12 | 14 | 110 | 110 | 220 | 40 | 34,6 | 11,5 | 13,4 |
| M16 | 18 | 125 | 125 | 250 | 60 | 47,9 | 16,0 | 24,9 |
| M20 | 24 | 170 | 170 | 340 | 100 | 81,4 | 27,1 | 39,2 |
Safety factor of 3.0 load stress
80 ml 2-component cartridges.
Shelf life: 18 month in sealed original packaging, sheltered from weather conditions and humidity and stored between 5ºC and not above 25ºC.
(Statistical data obtained under standard conditions)
| Density | 1,80 Kg/dm³ |
| Colour | Light Grey (Comp. A: beige; Comp. B: black) |
| Resistance to compression (ASTM D695) | 63 N/mm² |
| Compression module (ASTM D695) | 6300 N/mm² |
| Open time and speed of curing | |
| Application temperature | Open time | Curing time |
| 5º C | 15 min. | 120 min. |
| 10º C | 12 min. | 90 min. |
| 20º C | 6 min. | 45 min. |
| 30º C | 3 min. | 20 min. |
The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.
GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.
In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.
The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.