Cementitious adhesive of mixed binders with excellent workability, endowed with flexibility, great adhesion, with reduced slip and extended open time, for laying interior and exterior pavements and walls. Specially recommended for façades, big surfaces floors and underfloor heating. Suitable for gypsum or anhydrite substrates and very tough applications or those requiring the flexibility of the product.
Single-component, high-resistance cement-based product, with selected aggregates, additives and synthetic resins that guarantee high bond strength, excellent workability, resistance against ageing and great flexibility.
NOTE: The shorter the time between combing and laying the tile, the better results will be obtained.
Maximum weight on vertical surfaces: 60 kg/m²
Type of tile | Longer side cm | Trowel used for the application of the adhesive to the substrate | Trowel used for the application of the adhesive On the back side of the tile |
Mosaic | ≤ 10 cm | V 3 | - |
Ceramic tile |
≤ 20 cm | U 6 | - |
≤ 30 cm | U 6 | - | |
≤ 45 cm | U 8 | - | |
≥ 45 cm | U 8 | Smooth | |
≤ 120 cm | U 10 - R 10 | Smooth | |
≥ 120 cm | U 12 - R 12 | Smooth / V 3 / U 3 | |
Ceramic sheet >3 mm - ≤ 6 mm |
≤ 90 cm | U 6 | Smooth |
≤ 260 cm | U 8 | Smooth / V 3 / U 3 | |
Ceramic sheet >6 mm - ≤ 9 mm |
≤ 360 cm | U 10 | Smooth / V 3 / U 3 |
NOTE 1: In the case of extruded tiles or those with a pronounced back, a back buttering method is always required using the smooth side of the trowel, regardless of the tile format. |
Dimensioning of expansion joints
Scope of application | Location and dimensions | Joint width mm |
Exterior walls | - Bellow each floor slab - Separation length 3 m - 4 m linear - Maximum regular area 16 m2 |
≥ 8 mm |
Interior floors | - Respect open contraction joints. - Otherwise: linear separation lengths ≤ 8 m. - Maximum regular area. 40 m2 |
≥ 5 mm |
Exterior floors | - Separation length 2.5 m - 5 m linear - Maximum regular area. 16 m2 |
≥ 8 mm |
Singular points | - Door steps - Changes of floor |
|
NOTE: When these joints affect all layers of the ceramic system, they must meet the conditions of contraction joints. |
Sizing of perimeter joints
Scope of application | Location and dimensions | Joint width mm |
Interior walls | - Perimeter joints - Wall /ceiling joint |
≥ 8 mm |
- Wall / wall joint | ≥ 5 mm | |
Exterior walls | - Interior corners of the building - Exterior corners of the building |
≥ 8 mm |
Interior floors - Monolithic - Floating |
- Perimeter joints and joints with other elements or devices | |
Exterior floors | - Perimeter joints and joints with other elements or devices | |
Singular points | - Joints at encounters with carpentry | ≥ 5 mm |
25 kg plastic-lined paper bags.
Shelf life: 1 year in sealed original packaging, sheltered from weather conditions and humidity.
(Statistical data obtained under standard conditions)
Aspect | WHITE powder |
Adjustment time | Aprox.30 min. (depending on weather conditions) |
Paste life | Aprox 2 hours (depending on weather conditions) |
Initial tensile adhesion strenght | ≥ 1,0 N/mm2 |
Tensile adhesion strenght after water inmersion | ≥ 1,0 N/mm2 |
Tensile adhesion strenght after heat ageing | ≥ 1,0 N/mm2 |
Tensile adhesion strenght after freeze-thaw cycles | ≥ 1,0 N/mm2 |
Service temperature | -30ºC a 90ºC |
UNE-EN 12004 Classification | C2 TE |
UNE-EN 12002 Classification | S2 |
Approximate yield | Simple gluing: 4 Kg/m2 |
Double gluing: 6 Kg/m2 |
The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.
GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.
In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.
The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.