Traditerm® Taco de Anclaje

Anchor used to fasten insulation panels in the TRADITERM® System. Traditerm® Anchor is made of polyethylene and consists of two elements differentiated (nail and sheath). It is a percussion anchorage plug, used to fix the panels insulation in the TRADITERM Exterior Thermal Insulation System. It is easy to apply. It ensures a perfect fixing of the plates to the support. Resistant to oxidation. Wide range of product sizes for correct adaptation to thermal insulation systems depending on the thickness of the plate. European approval according to ETA-16/0509.


Download technical data sheet


Additional information

Technical Caracteristics

The anchor is formed of two elements:

  • Nail: fiberglass reinforced polyamide
  • Sheath: polyethylene

Advantages and Uses

  • Easy to apply.
  • Ensures perfect fastening of the panels to the substrate.
  • Resistant to oxidation.
  • Range of sizes, depending on the thickness of the panel.
  • Anchor with European certification.

Application Procedure

  • After 24 hours from the fixing of the insulation boards to the facade with TRADITERM adhesive, using a drill, make a hole in the support, passing through the insulating panel. The depth of the hole in the bracket must be 60 mm.
  • Place the TRADITERM® TACO DE ANCLAJE in the hole made.
  • With the help of a mallet, hit the anchor so that it penetrates until it cuts the surface by 1-2 mm of the insulation board.
  • Subsequently, the recess produced on the surface of the insulating panel is regularized with the mortar TRADITERM®.

Recommendations

  • The plug must be inserted at least 50 mm into the holder.
  • The plug must cut the insulation panel by 1-2 mm. If the plug is not inserted into the insulation, the insulation will marked on the final finish.
  • Check that the blocks are securely fixed.
  • Hammering into studs with nails already installed is not recommended as it may cause damage to the plate.
  • The hole in solid materials should be cleaned of any debris prior to installation.
-Salto de página-
  • Depending on the thickness of the insulation panel, the following thicknesses of TRADITERM® TACO DE ANCLAJE are recommended:
Type of anchor TRADITERM insulation board thickness (mm) Anchor block length (10 mm thick adhesive mortar layer + 20 mm thick existing plaster layer)     Minimum number of anchors / m² (usual situations) Homologation anchor block
Substrates type A,B,C y D Substrates type E 6 ETA-16/0509

Traditerm® Taco de Anclaje

 
30 90 110
40 110 120
50 110 140
60 120 140
70 140 160
80 140 160
90 160 180
100 160 180
120 180 200
140 200 220
150 220 260
160 220 260
180 260 260
200 260 -

Packaging and Storage

Boxes with the following format (depending on the length of the anchor):

Traditerm Taco de Anclaje 90 mm Boxes of 200 units
Traditerm Taco de Anclaje 110 mm Boxes of 200 units
Traditerm Taco de Anclaje 120 mm Boxes of 200 units
Traditerm Taco de Anclaje 140 mm Boxes of 200 units
Traditerm Taco de Anclaje 160 mm Boxes of 200 units
Traditerm Taco de Anclaje 180 mm Boxes of 200 units
Traditerm Taco de Anclaje 200 mm Boxes of 200 units
Traditerm Taco de Anclaje 220 mm Boxes of 100 units
Traditerm Taco de Anclaje 260 mm Boxes of 100 units

Keep the anchors protected from the weather and solar radiation.

 

Technical data

(Data obtained in a laboratory under standard conditions)

Composition Polypropylene
Pre-drill diameter 10mm
Drilling depth in holder 60mm
Washer diameter  60mm
Anchorage depth 50mm
Homologation ETA-16/0509
Performance 8 units/m2

 

Notas

The information and instructions in this datasheet are based on our current tests and technical knowledge. They are intended as general guidance and do not constitute a binding commitment by PIDILITEPUMA MEA CHEMICALS LLC. It is the sole responsibility of the user to verify, prior to use, that the product is suitable for the intended application and to ensure that it is applied correctly and in accordance with applicable regulations and good industry practice.

PIDILITEPUMA MEA CHEMICALS LLC cannot control how its products are applied on site throughout the entire project and therefore cannot accept responsibility for their application by contractors or other parties involved in the execution of the work. Support visits to the jobsite by our technical staff do not change that. Our responsibility is limited exclusively to defects that can be directly attributed to the supplied products, whether used individually or as part of a system, caused by manufacturing defects.

 

It is the responsibility of the project designer, site manager, contractor, or other relevant professionals to ensure that the selected products are appropriate for the specific project, taking into account their properties, the substrate, site conditions, and any existing issues.

In the event of a claim, the original packaging must be provided to ensure proper product traceability.

Any performance values stated for PIDILITEPUMA MEA CHEMICALS LLC products or construction solutions, whether in UNE standards or other applicable standards, are based solely on the specific test conditions defined in those standards (such as substrate type, temperature, and humidity). These values may not apply to situations where products are tested or used under different conditions.