A set of unidirectional carbon fibre yarns of high mechanical resistance, housed inside a cotton thread net that gives them a "rope" appearance. Once stiffened with epoxy adhesive, they are used to anchor and structurally connect CARBOTEC systems or other types of structural reinforcement systems to the foundation to be reinforced.
Unidirectional carbon fibre.
PLACEMENT AFTER REINFORCEMENT
PLACEMENT PRIOR TO REINFORCEMENT
Rolls of 10 m length. Available diametres: 8, 10, and 12 mm Store in their original unopened containers in a cool, dry place at temperatures between 5 and 30 ºC and always away from direct sunlight and the weather.
| 8 mm | |
| Diametre | 8 mm |
| Equivalent area | 21,24 mm2 |
| Resistance to the traction | 5.100 MPa |
| Elastic model | 245 gPA |
| Fibre weight | 43±5% g/ml |
| Density | 1.78 g/cm3 |
| Elongation at break | 2,10% |
| 10 mm | |
| Diametre | 10 mm |
| Equivalent area | 26,80 mm2 |
| Resistance to the traction | 5.100 MPa |
| Elastic model | 245 gPA |
| Fibre weight | 60±5% g/ml |
| Density | 1.78 g/cm3 |
| Elongation at break | 2,10% |
| 12 mm | |
| Diametre | 12 mm |
| Equivalent area | 31,40 mm2 |
| Resistance to the traction | 5.100 MPa |
| Elastic model | 245 gPA |
| Fibre weight | 68±5% g/ml |
| Density | 1.78 g/cm3 |
| AElongation at break | 2,10% |
The information and instructions in this datasheet are based on our current tests and technical knowledge. They are intended as general guidance and do not constitute a binding commitment by PIDILITEPUMA MEA CHEMICALS LLC. It is the sole responsibility of the user to verify, prior to use, that the product is suitable for the intended application and to ensure that it is applied correctly and in accordance with applicable regulations and good industry practice.
PIDILITEPUMA MEA CHEMICALS LLC cannot control how its products are applied on site throughout the entire project and therefore cannot accept responsibility for their application by contractors or other parties involved in the execution of the work. Support visits to the jobsite by our technical staff do not change that. Our responsibility is limited exclusively to defects that can be directly attributed to the supplied products, whether used individually or as part of a system, caused by manufacturing defects.
It is the responsibility of the project designer, site manager, contractor, or other relevant professionals to ensure that the selected products are appropriate for the specific project, taking into account their properties, the substrate, site conditions, and any existing issues.
In the event of a claim, the original packaging must be provided to ensure proper product traceability.
Any performance values stated for PIDILITEPUMA MEA CHEMICALS LLC products or construction solutions, whether in UNE standards or other applicable standards, are based solely on the specific test conditions defined in those standards (such as substrate type, temperature, and humidity). These values may not apply to situations where products are tested or used under different conditions.