Implarest® EP
Epoxy 100% solid, two-component adhesive, specially formulated for bonding new and old concrete. Once mixed a semi-fluid liquid is obtained which may be applied above 10ºC. It can be used as protection barrier of the steel of the reinforced concrete. It will be applied on the clean reinforcement.
Resin based epoxy product and a hardener.
PREPARATION OF THE CONCRETE SURFACE:
PREPARATION OF THE SURFACE OF THE ARMOR:
MIXTURE:
APPLICATION:
Application as bonding primer
Application as a protective primer for reinforcement armor
CURING:
Two-component predosified sets:
Shelf life: up to 24 months in sealed original packaging, sheltered from weather conditions and humidity.
(Statistical data obtained under standard conditions)
| Colour | White-Beige |
| Density | 1.55 ± 0.05 kg/l |
| Viscosity of mixture | 4,000 – 6,000 m.Pa.s a 20ºC |
| Weight solids | 100% |
| Recommended consumption | 0.4 – 1 Kg/m² according to substrate rugosity |
| Mixture proportion | Base / Reactor = 100:20 parts in weight |
| Pot-life (250 g): 10ºC 20ºC 30ºC |
2.5 hours 1.5 hours 1 hour |
| Bonding open time: 10ºC 20ºC 30ºC |
7 hours 4.5 hours 3 hours |
| Application | Brush, roller or airless spray |
| Hardness Shore D | 80 (DIN 53505) |
| GRUPO PUMA SL Avd. Agrupación Córdoba, Núm.17 14014 (Córdoba) 12 Nº: 502-2287-1 |
|
|
EN-1504-4 |
|
| Bonding/Adhesion | Pass |
| Resistance ti shear stress | >6 N/mm2 |
| Resistance to compression | ≥ 30 N/mm2 |
| Retraction / Dilatation | ≤ 0.1% |
| Workability | ≤ 45 min |
| Sensibility to water | Pass |
| Elasticity module | ≥ 2000 N/mm2 |
| Thermal dilation coefficient | ≤100 μm/mºC |
| Glass transition temperature | ≥ 40ºC |
| Reaction to fire | NPD |
| Durability | Pass |
| Hazardous substances | According to point 5.4 |
|
GRUPO PUMA SL |
|
|
EN 1504-7 |
|
| Diffusion resistance | NPD |
| Protection against corrosion and workability | Pass |
| Durability | Pass |
| Glass transition temperature | 10 k over the maximum of service |
| Shear adhesion (pull strength) | NPD |
| Hazardous substances | According to point 5.3 |
The information and instructions in this datasheet are based on our current tests and technical knowledge. They are intended as general guidance and do not constitute a binding commitment by PIDILITEPUMA MEA CHEMICALS LLC. It is the sole responsibility of the user to verify, prior to use, that the product is suitable for the intended application and to ensure that it is applied correctly and in accordance with applicable regulations and good industry practice.
PIDILITEPUMA MEA CHEMICALS LLC cannot control how its products are applied on site throughout the entire project and therefore cannot accept responsibility for their application by contractors or other parties involved in the execution of the work. Support visits to the jobsite by our technical staff do not change that. Our responsibility is limited exclusively to defects that can be directly attributed to the supplied products, whether used individually or as part of a system, caused by manufacturing defects.
It is the responsibility of the project designer, site manager, contractor, or other relevant professionals to ensure that the selected products are appropriate for the specific project, taking into account their properties, the substrate, site conditions, and any existing issues.
In the event of a claim, the original packaging must be provided to ensure proper product traceability.
Any performance values stated for PIDILITEPUMA MEA CHEMICALS LLC products or construction solutions, whether in UNE standards or other applicable standards, are based solely on the specific test conditions defined in those standards (such as substrate type, temperature, and humidity). These values may not apply to situations where products are tested or used under different conditions.