Normal-setting flowing screed mortar for the preparation of floors subject to pedestrian traffic, for interior and exterior use, which, once hardened, shall be covered with discontinuous floor coverings (parquet, carpet, ceramic tiles, vinyl flooring, etc.). This flowing screed mortar is suitable for use with underfloor heating systems.

13813 - CT C25 F6 B2

Download technical data sheet


Additional information

Technical Caracteristics

Product based on cement, selected aggregates, and additives.

Advantages and Uses

  • Screeding and levelling of interior and exterior floors for pedestrian traffic. 
  • Suitable for radiant heating floors.
  • Easy to apply, providing surfaces with high flatness. 
  • High mechanical strengths.
  • Floor screed for thicknesses between 10–60 mm.
  • Particularly suitable as a screed prior to the installation of ceramic tiles in exterior applications.

Suitable Substrates

  • Concrete, mortar floors and similar.
  • Substrates must be resistant enough, stable, sound, and clean. Free of dust, release agents, organic products, etc.
  • Prior to the application of PAVILAND RECRECIDO, any honeycombs and/or cracks present in the substrate must be properly repaired.
  • Before applying the product, make sure that residual moisten is below the recommended one (bellow 3%).
  • Apply Paviland Primer R to avoid the formation of air bubbles in the render and improve its adhesion to the substrate.

Application Procedure

  • Define and mark the maximum levels of the screed layer.
  • Mix the product with water, starting at 16% of the dry weight until the desired consistency is achieved, without exceeding 18% (between 4.0 and 4.5 litres per 25 kg bag). Mechanically mix using low-speed mortar mixers (< 500 r.p.m.) until a fluid and homogeneous paste is obtained (free of lumps).
  • Apply the mixed product by pouring or pumping it onto the substrate and spread it using a levelling trowel, smoothing, and correcting any imperfections.
  • For large areas, it is recommended to pump the mixture using twin-spiral mixers capable of delivering 20–40 L/min. This procedure helps to optimise installation times.
  • Once the product has been spread, it is recommended to pass a spiked roller over the surface to remove air bubbles, then re-smooth with the levelling trowel to achieve a completely smooth surface.
  • 10 to 60 mm thickness.
  • Respect structural joints and create perimeter and partition joints.

Recommendations

  • Do not apply the product under 5ºC nor above 30ºC temperature.
  • Do not apply under the risk of frost, rain, heavy wind, or direct sun light. Do not apply on moisten floors.
  • Do not add sand, cement, or any other material that may alter the original formulation. 
  • Once the product has been mixed, and its resting time has elapsed, do not add any water.
  • For floors with a surface area greater than 20 m² or a linear length exceeding 10 metres, it is recommended to create partition joints, dividing the surface into approximately square panels with a minimum width of 6 mm, filled with PUMALASTIC PU.
  • Avoid contact with perimeter elements by creating perimeter joints with a minimum width of 6 mm and a depth between 10 and 30 mm, filled with PUMALASTIC PU.
  • Before installing the final floor covering, check with a carbide hygrometer that the residual moisture is < 3%.
  • For exterior applications, it is essential to protect the screed from direct sunlight for the first 24 hours and from rain until the final floor covering is installed.

Packaging and Storage

25 Kg plastic bags. 
Store up to 1 year in its original closed container, away from extreme weather conditions and humidity.

Technical data

(Statistic results obtained under standard conditions)

Appearance GREY powder
Granularity < 3 mm
Kneading water 17 % ± 1
Waiting time before stepping on 24 hours
Compressive strength (28 days) (EN 13892-2) >25 N/mm²
Flexural strength (28 days) (EN 13892-) >6 N/mm²
Tensile strength (28 days) (EN 13892-8) >2 N/mm²
Shrinkage (EN 13872: 2004) < 0.5 mm/m
Thermal conductivity  (λ, tabulated value)  1.10-1.30 W/mk
Performance 20Kg/m2 and thickness cm
Classification (according to EN 13813) CT C25 F6 B2,0
Reaction to fire A1 Type

NOTE: Timings are given according to temperatures of 23ºC and 50% relative humidity. Periods of time will be shorter at higher temperatures and longer at lower temperatures.

CE Mark

GRUPO PUMA ESPAÑA, S.L 
Avda. AGRUPACIÓN CÓRDOBA, Núm. 17 
14014 CÓRDOBA  
26

PAVILAND RECRECIDO
Nº. 501040
EN 13813
Normal-setting cementitious flowing screed mortar, type CT-C25-F6-B2.0, for the preparation
of floors subject to pedestrian traffic, for interior and exterior use, prior to the installation of floor renders. For thicknesses from 10 to 60 mm

Reaction to fire A1 Type
Hazardous substances emission CT
Compressive strength of concrete. C25
Flexural strength F6
Tensile strength   B2,0

 

Legal Disclaimer

Instructions given on how to use the product are given based on our tests and knowledge and do not imply any commitment from GRUPO PUMA and do not exempt the user from checking and verifying the products before using them. Claims must be presented with the original packaging to allow an adequate traceability.

GRUPO PUMA is not responsible, under any circumstances, for the application of its products or constructive solutions by the applicator company or other subjects involved in the application and / or execution of the work in question, limiting the responsibility of GRUPO PUMA exclusively to possible damages attributable directly and exclusively to the products supplied,  individual or integrated into systems, due to failures in their manufacture.

In any case, the creator of the work project, the technical management or person in charge, or subsidiarity the application company or other possible people involved in the application and / or execution of the work in question, must ensure the suitability of the products. Taking always into account the substrates and any possible pathologies that may occur in the workplace itself.

The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.